Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Language: EN

Blauberg CIVIC EC LB

CIVIC EC LB
CIVIC EC LB
zoom

The CIVIC EC LB units are designed for single-room ventilation of schools, offices and other public and commercial premises. Air flow up to 1240 m³/h.
Model features
  • Description
  • Modifications
  • Capacity diagram
  • Downloads
  • Designation key
  • Accessories
Description
Description
FEATURES

The CIVIC EC LB units are designed forsingle-room ventilation of schools, offices and other public and commercial premises.Offer the ideal simple and efficient ventilation solutions for existing and renovated buildings and require no layout of air ducts.Efficient supply and extract ventilation for separate premises.EC motors with low energy consumption.Low-noise operation.
Simple mounting.

DESIGN MOTORS

Made of high-quality polymer coated steel, internally lined with heat- and sound insulation of mineral wool or other materials.Built-in preheater and reheater modifications available for cold climate conditions.

High efficient electronically commutated motors with external motor and impeller with forward curved blades. Such motors are the most state-of-the-art energy saving solution.EC motors are featured with high performance and total speed controllable range. High efficiency reaching 90 % is the premium advantage of the electronically commutated motors.

AIR FILTRATION

Supply and extract air is purified by a set of panel filters. Filtering class depends on the unit model.Panel G4 filter is used for extract air filtration.

BYPASS CONTROL AND AUTOMATION

The units are equipped with a bypass. The bypass damper opens for free cooling ventilation mode in summer.

The CIVIC EC LB… S21 units are equipped with an integrated automation system.
The S21 controller allows integrating the unit into the BMS (Building Management System).
The unit can be controlled by the Blauberg AHU mobile application via Wi-Fi.

Download
the Blauberg AHU
app for Android

Download
the Blauberg AHU
app for iOS
 
AIR DAMPERS

The automatic supply and extract air dampers are used to prevent uncontrollable air draughts during the unit standstill.

HEATERS

PREHEATING

CIVIC EC LBE and CIVIC EC LBE2 units are equipped with an electric preheater which protects the heat exchanger from freezing.

REHEATING

CIVIC EC LBE2 units feature an electric reheater to raise the supply air temperature.

HEAT EXCHANGER AUTOMATION FUNCTIONS

The CIVIC EC LB unit has a counter-flow heat exchanger made of polystyrene.

• In cold season the heat energy of the extract air flow is absorbed by intake air flow, thus decreasing the heat losses caused by ventilation. Condensate generated during heat recovery is collected in a drain pan and removed to the sewage system.

• In warm season the heat of the outdoor air is absorbed by extract air flow. This way the supply air temperature decreases and heat recovery reduces operation loads for the air conditioner.

The CIVIC EC LB... -E unit is equipped with a counter-flow heat exchanger made of enthalpy membrane.

• In cold season the heat and moisture of the extract air are absorbed by supply air through the enthalpy membrane. thus decreasing the heat losses caused by ventilation.

• In warm season the heat and humidity of the outdoor air is absorbed by extract air flow through the enthalpy membrane. This way the supply air temperature and humidity decreases and heat recovery reduces operation loads for the air conditioner.

 
Functions

CIVIC EC LB… S21

Unit control via Wi-Fi using the mobile application +
Unit control via remote control panel
S22 control panel (option)
Unit control via remote wireless control panel
S22 Wi-Fi control panel (option)
Unit control via a wired remote LCD control panel
S25 control panel (option)
BMS (Building Management System)  RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
Blauberg Cloud Server service +
Speed switch +
Filter replacement indication by filter timer
Alarm indication full alarm description in the mobile application
Week scheduled operation +
Bypass automatic
manual
Timer +
Boost mode +
Fireplace mode +
Freeze protection using cyclical stops of the supply fan
using preheating (option)
Reheater connection option
Cooler connection option
Minimum supply air temperature control +
Humidity control option
CO₂ control option
VOC control option
PM2.5 control option
Fire alarm sensor connection option
Option: the functionality is available when purchasing the appropriate accessory (see the "Accessories" section)
FUNCTIONING

Cold outside air flows through the filters and heat exchanger and is moved to the room with a supply centrifugal fan.

Warm polluted air from the premise flows through the filter and the heat exchanger and is exhausted outside with an extract centrifugal fan.

Modifications
Modification name
CIVIC EC LB 1200 S21
CIVIC EC LB 300 S21
CIVIC EC LB 500 S21
+
+
+
Capacity diagram
Capacity diagram
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
CIVIC EC LB - data sheet (pdf 1.25Mb)
CIVIC EC LB - image (png 270.9Kb)
CIVIC EC LB - user's manual (pdf 9.19Mb)
S21 - user's manual (pdf 1.37Mb)
S14 - user's manual (pdf 1.38Mb)
CIVIC EC LB 1200 - image (png 355.94Kb)
Modbus table for connecting S21 automation to BMS - user's manual (pdf 140.84Kb)
CIVIC EC LB 1200 - user's manual (pdf 3.36Mb)
CIVIC EC LB 1200 V.2 - user's manual (pdf 3.64Mb)
AH CIVIC EC LB - installation instruction (pdf 1.39Mb)
Designation key
Designation key
Model Motor type Mounting Bypass Heater Drain pump Rated air flow [m³/h] Heat exchanger type Control
CIVIC EC: synchronous electronically commutated motor L: floor mounting B: with bypass

_: without heater
E:
preheating
E2:
preheating + reheating

_: without drain pump
CP: with drain pump

300; 500; 1200 _: heat recovery
-E: energy recovery
S21
Accessories
Accessories
  Civic EC LB... 300 S21 Civic EC LB... 500 S21 Civic EC LB... 1200 S21
Outer ventilation hood made of brushed stainless steel AH Civic 300 LB chrome AH Civic 500 LB chrome AH Civic 1200 LB chrome 
Outer ventilation hood made of white coated steel AH Civic 300 LB white AH Civic 500 LB white AH Civic 1200 LB white 
G4 filter FP 308x238x22 G4 PPI FP 450x257x27 G4 PPI FP 450x395x48 G4 PET 
G4 filter FP 265x213x48 G4  FP 318x290x22 G4  FP 540x450x48 G4
F7 filter - - FP 540x450x48 F7 
F8 filter FP 384x273x60 F8  FP 318x290x60 F8 -
 F8 carbon filter FP 533x135x48 F8 C FP 666x196x48 F8 C -
H11 HEPA filter FP 533x135x60 H11 FP 666x196x60 H11 -
Control panel S22 S22 S22
Wi-Fi control panel S22 Wi-Fi S22 Wi-Fi S22 Wi-Fi
LCD Control panel S25 S25 S25
VOC sensor DPWQ30600 DPWQ30600 DPWQ30600 
CO₂ sensor DPWQ40200 DPWQ40200 DPWQ40200
Humidity sensor DPWС11200 DPWС11200 DPWC11200
CO₂ sensor with indication CD-1 CD-1 CD-1
CO₂ sensor CD-2 CD-2 CD-2
Internal humidity sensor  FS2 FS2 FS2
Humidity sensor HR-S HR-S HR-S
Syphon kit  SFK 20x32 SFK 20x32  SFK 20x32
Drain pump CP-2 CP-2 CP-2