Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Single-room reversible units Vento
  • Single-room units Freshbox
  • Single-room ventilation units Civic
Additionally
Show ×
Voltage
Functions
Remote control panel
Heating
Mounting
Hide filters
Fault
%
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Print version
Search results
Selected 34 products
Mode VoltageMountingAir ductCasing materialEC motorHeatingCurrentPowerMaximum air flowSound pressure levelFrequencyRPMSpeedFilter: extract/supplyHeat recovery efficiencyTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 m distanceHeat exchanger typeHeat exchanger materialFan powerSound pressure level at 1 mSound pressure level at 3 mTransported air temperature Connected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeFilterTemperature of transported airOutdoor sound pressure attenuation in accordance with DIN EN 20140Insulating materialHeat recovery efficiencyVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPWeightExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMax. power without electric heaterMax. unit current without electric heaterMax. unit current with electric heaterPreheater power consumptionMax. current consumption with heater(s)Sound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Remote control panelFunctionsIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8*
Freshbox E-100 ERV
Speed I
230 wall mounting - polymer coated steel yes electric preheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 90 - - - 10 8 - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 3.6 700 - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-100 ERV
Speed II
230 wall mounting - polymer coated steel yes electric preheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 86 - - - 10 17 - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 3.6 700 - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-100 ERV
Speed III
230 wall mounting - polymer coated steel yes electric preheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 83 - - - 10 28 - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 3.6 700 - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
FRESHBOX 60 (1 speed) 100-240 wall mounting - - - without heating 0.02 4.2 30 22 50/60 1165 - G2 79 - 10.3 - -20 bis +50 B - - - counter-flow polystyrene - - - - - - - - - - - - 100-240 - - - - - - - - - - - - - - - - - - - Sensor - - - -
FRESHBOX 60 (2 speed) 100-240 wall mounting - - - without heating 0.04 9.6 45 25 50/60 1720 - G2 74 - 10.3 - -20 bis +50 B - - - counter-flow polystyrene - - - - - - - - - - - - 100-240 - - - - - - - - - - - - - - - - - - - Sensor - - - -
FRESHBOX 60 (3 speed) 100-240 wall mounting - - - without heating 0.07 15.4 60 29 50/60 2685 - G2 70 - 10.3 - -20 bis +50 B - - - counter-flow polystyrene - - - - - - - - - - - - 100-240 - - - - - - - - - - - - - - - - - - - Sensor - - - -
Freshbox E2-100 ERV black
Speed I
230 wall mounting - polymer coated steel yes electric preheating, electric reheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 90 - - 350 10 8 - - G4 G4 - - 12 0.4 5.2 700 - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100 ERV black
Speed II
230 wall mounting - polymer coated steel yes electric preheating, electric reheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 86 - - 350 10 17 - - G4 G4 - - 21 0.4 5.2 700 - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100 ERV black
Speed III
230 wall mounting - polymer coated steel yes electric preheating, electric reheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 83 - - 350 10 28 - - G4 G4 - - 45 0.4 5.2 700 - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
VENTO Expert A100-1 S W V.2 (Speed I) 100-240 - 160 - yes - 0.037 - - - 50/60 780 - - - - - - - - IP24 - - - - 3.20 - - - - 18 9 - -20 … +40 42 - - - - - - - 1.28 - - - 5 3 - - - - - 23 13 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
VENTO Expert A100-1 S W V.2 (Speed II) 100-240 - 160 - yes - 0.046 - - - 50/60 1100 - - - - - - - - IP24 - - - - 4.00 - - - - 30 15 - -20 … +40 42 - - - - - - - 0.96 - - - 8 4 - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
VENTO Expert A100-1 S W V.2 (Speed III) 100-240 - 160 - yes - 0.071 - - - 50/60 1920 - - - - - - - - IP24 - - - - 6.60 - - - - 58 29 - -20 … +40 42 - - - - - - - 0.82 - - - 16 8 - - - - - 40 30 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
VENTO Expert A100-1 S W V.2 (MAX) 100-240 - 160 - yes - 0.151 - - - 50/60 2940 - - - - - - - - IP24 - - - - 18.00 - - - - 108 54 - -20 … +40 42 - - - - - - - 1.20 - - - 30 15 - - - - - 51 42 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
Vento Expert A50-1 S10 W V.2 (1 speed) 100-240 wall mounting 160 - yes - 0.035 - - - 50/60 800 - - - - - 4.45 - - IP24 - - - - - - - -20...+40 - 15 8 - - 42 - - - - - - - 2.14 - - - 4 2 - - - - - 20 11 G3 (Option: F8 PM2,5 > 99 %*) up to 93 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
Vento Expert A50-1 S10 W V.2 (2 speed) 100-240 wall mounting 160 - yes - 0.040 - - - 50/60 1300 - - - - - 5.08 - - IP24 - - - - - - - -20...+40 - 30 15 - - 42 - - - - - - - 1.22 - - - 8 4 - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 93 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
Vento Expert A50-1 S10 W V.2 (3 speed) 100-240 wall mounting 160 - yes - 0.059 - - - 50/60 1900 - - - - - 7.06 - - IP24 - - - - - - - -20...+40 - 50 25 - - 42 - - - - - - - 1.02 - - - 14 7 - - - - - 30 21 G3 (Option: F8 PM2,5 > 99 %*) up to 93 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
Freshbox E2-100 ERV WiFi
Speed I
230 - - polymer coated steel - electric preheating, electric reheating - - 30 - 50/60 2200 I - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 96 - - 350 10 8 - 31 G4 G4 - - 20 0.4 5.2 700 - - 13 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100 ERV WiFi
Speed II
230 - - polymer coated steel - electric preheating, electric reheating - - 44 - 50/60 2200 II - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 94 - - 350 10 12 - 31 G4 G4 - - 23 0.4 5.2 700 - - 20 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100 ERV WiFi
Speed III
230 - - polymer coated steel - electric preheating, electric reheating - - 60 - 50/60 2200 III - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 92 - - 350 10 17 - 31 G4 G4 - - 29 0.4 5.2 700 - - 27 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100 ERV WiFi
Speed IV
230 - - polymer coated steel - electric preheating, electric reheating - - 75 - 50/60 2200 IV - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 89 - - 350 10 21 - 31 G4 G4 - - 37 0.4 5.2 700 - - 33 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100 ERV WiFi
Speed V
230 - - polymer coated steel - electric preheating, electric reheating - - 100 - 50/60 2200 V - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 87 - - 350 10 28 - 31 G4 G4 - - 53 0.4 5.2 700 - - 39 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-100 ERV black
Speed I
230 wall mounting - polymer coated steel yes electric preheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 90 - - - 10 8 - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 3.6 700 - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-100 ERV black
Speed II
230 wall mounting - polymer coated steel yes electric preheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 86 - - - 10 17 - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 3.6 700 - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-100 ERV black
Speed III
230 wall mounting - polymer coated steel yes electric preheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 83 - - - 10 28 - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 3.6 700 - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV
Speed I
230 wall mounting - polymer coated steel yes electric reheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 96 - - 350 10 8 - - G4 G4 - - 12 0.4 1.94 - - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV
Speed II
230 wall mounting - polymer coated steel yes electric reheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 89 - - 350 10 17 - - G4 G4 - - 21 0.4 1.94 - - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV
Speed III
230 wall mounting - polymer coated steel yes electric reheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 83 - - 350 10 28 - - G4 G4 - - 45 0.4 1.94 - - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100
Speed I
110-240 wall mounting - polymer coated steel yes without heating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 98 - - - 10 8 - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 - - - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100
Speed II
110-240 wall mounting - polymer coated steel yes without heating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 92 - - - 10 17 - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 - - - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100
Speed III
110-240 wall mounting - polymer coated steel yes without heating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 89 - - - 10 28 - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 - - - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100
Speed I
230 wall mounting - polymer coated steel yes electric preheating, electric reheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 98 - - 350 10 8 - - G4 G4 - - 12 0.4 5.2 700 - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100
Speed II
230 wall mounting - polymer coated steel yes electric preheating, electric reheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 92 - - 350 10 17 - - G4 G4 - - 21 0.4 5.2 700 - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100
Speed III
230 wall mounting - polymer coated steel yes electric preheating, electric reheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 89 - - 350 10 28 - - G4 G4 - - 45 0.4 5.2 700 - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
VENTO Expert A50-1 S W V.2 (1 speed) 100-240 wall mounting 160 - yes - 0.035 - - - 50/60 800 - - - - - 4.45 - - IP24 - - - - - - - - - 15 8 - -20...+40 42 - - - - - - - 2.14 - - - 4 2 - - - - - 20 11 G3 (Option: F8 PM2,5 > 99 %*) up to 93 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
VENTO Expert A50-1 S W V.2 (2 speed) 100-240 wall mounting 160 - yes - 0.040 - - - 50/60 1300 - - - - - 5.08 - - IP24 - - - - - - - - - 30 15 - -20...+40 42 - - - - - - - 1.22 - - - 8 4 - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 93 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
VENTO Expert A50-1 S W V.2 (3 speed) 100-240 wall mounting 160 - yes - 0.059 - - - 50/60 1900 - - - - - 7.06 - - IP24 - - - - - - - - - 50 25 - -20...+40 42 - - - - - - - 1.02 - - - 14 7 - - - - - 30 21 G3 (Option: F8 PM2,5 > 99 %*) up to 93 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
Freshbox E-200 ERV WiFi
Speed I
230 - - polymer coated steel - electric preheating - - 30 - 50/60 2000 I - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 85 - - 30 8 - 55 G4 G4 + F7 (Option: H13) - - 10 - - 650 4.0 - 12 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-200 ERV WiFi
Speed II
230 - - polymer coated steel - electric preheating - - 60 - 50/60 2000 II - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 81 - - 30 17 - 55 G4 G4 + F7 (Option: H13) - - 15 - - 650 4.0 - 22 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-200 ERV WiFi
Speed III
230 - - polymer coated steel - electric preheating - - 90 - 50/60 2000 III - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 75 - - 30 25 - 55 G4 G4 + F7 (Option: H13) - - 25 - - 650 4.0 - 30 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-200 ERV WiFi
Speed IV
230 - - polymer coated steel - electric preheating - - 120 - 50/60 2000 IV - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 68 - - 30 33 - 55 G4 G4 + F7 (Option: H13) - - 44 - - 650 4.0 - 36 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-200 ERV WiFi
Speed V
230 - - polymer coated steel - electric preheating - - 200 - 50/60 2000 IV - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 66 - - 30 56 - 55 G4 G4 + F7 (Option: H13) - - 134 - - 650 4.0 - 45 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100 ERV WiFi
Speed I
110-240 - - polymer coated steel - without heating - - 30 - 50/60 2200 I - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 96 - - - 10 8 - 31 G4 G4 + F8 (Option: F8 Carbon; H13) - - 20 0.4 - - - - 13 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100 ERV WiFi
Speed II
110-240 - - polymer coated steel - without heating - - 44 - 50/60 2200 II - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 94 - - - 10 12 - 31 G4 G4 + F8 (Option: F8 Carbon; H13) - - 23 0.4 - - - - 20 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100 ERV WiFi
Speed III
110-240 - - polymer coated steel - without heating - - 60 - 50/60 2200 III - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 92 - - - 10 17 - 31 G4 G4 + F8 (Option: F8 Carbon; H13) - - 29 0.4 - - - - 27 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100 ERV WiFi
Speed IV
110-240 - - polymer coated steel - without heating - - 75 - 50/60 2200 IV - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 89 - - - 10 21 - 31 G4 G4 + F8 (Option: F8 Carbon; H13) - - 37 0.4 - - - - 33 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100 ERV WiFi
Speed V
110-240 - - polymer coated steel - without heating - - 100 - 50/60 2200 V - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 87 - - - 10 28 - 31 G4 G4 + F8 (Option: F8 Carbon; H13) - - 53 0.4 - - - - 39 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100 ERV black
Speed I
110-240 wall mounting - polymer coated steel yes without heating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 96 - - - 10 8 - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 - - - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100 ERV black
Speed II
110-240 wall mounting - polymer coated steel yes without heating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 89 - - - 10 17 - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 - - - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox 100 ERV black
Speed III
110-240 wall mounting - polymer coated steel yes without heating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 83 - - - 10 28 - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 - - - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-100
Speed I
230 wall mounting - polymer coated steel yes electric preheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 98 - - - 10 8 - - G4 G4, F8 (Option: F8 C, H13) - - 12 0.4 3.6 700 - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-100
Speed II
230 wall mounting - polymer coated steel yes electric preheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 92 - - - 10 17 - - G4 G4, F8 (Option: F8 C, H13) - - 21 0.4 3.6 700 - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E-100
Speed III
230 wall mounting - polymer coated steel yes electric preheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 89 - - - 10 28 - - G4 G4, F8 (Option: F8 C, H13) - - 45 0.4 3.6 700 - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100 black
Speed I
230 wall mounting - polymer coated steel yes electric preheating, electric reheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 98 - - 350 10 8 - - G4 G4 - - 12 0.4 5.2 700 - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100 black
Speed II
230 wall mounting - polymer coated steel yes electric preheating, electric reheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 92 - - 350 10 17 - - G4 G4 - - 21 0.4 5.2 700 - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-100 black
Speed I
230 wall mounting - polymer coated steel yes electric preheating, electric reheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 89 - - 350 10 28 - - G4 G4 - - 45 0.4 5.2 700 - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
VENTO Expert A100-1 S10 W V.2 (Speed I) 100-240 - 160 - yes - 0.037 - - - 50/60 780 - - - - - - - - IP24 - - - - 3.20 - - - - 18 9 - -20 … +40 42 - - - - - - - 1.28 - - - 5 3 - - - - - 23 13 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
VENTO Expert A100-1 S10 W V.2 (Speed II) 100-240 - 160 - yes - 0.046 - - - 50/60 1100 - - - - - - - - IP24 - - - - 4.00 - - - - 30 15 - -20 … +40 42 - - - - - - - 0.96 - - - 8 4 - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
VENTO Expert A100-1 S10 W V.2 (Speed III) 100-240 - 160 - yes - 0.071 - - - 50/60 1920 - - - - - - - - IP24 - - - - 6.60 - - - - 58 29 - -20 … +40 42 - - - - - - - 0.82 - - - 16 8 - - - - - 40 30 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
VENTO Expert A100-1 S10 W V.2 (MAX) 100-240 - 160 - yes - 0.151 - - - 50/60 2940 - - - - - - - - IP24 - - - - 18.00 - - - - 108 54 - -20 … +40 42 - - - - - - - 1.20 - - - 30 15 - - - - - 51 42 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2 -
Freshbox E2-200 ERV WiFi
Speed I
230 - - polymer coated steel - electric preheating, electric reheating - - 30 - 50/60 2000 I - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 85 - - 700 30 8 - 55 G4 G4 + F7 (Option: H13) - - 10 - - 650 7.2 - 12 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-200 ERV WiFi
Speed II
230 - - polymer coated steel - electric preheating, electric reheating - - 60 - 50/60 2000 II - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 81 - - 700 30 17 - 55 G4 G4 + F7 (Option: H13) - - 15 - - 650 7.2 - 22 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-200 ERV WiFi
Speed III
230 - - polymer coated steel - electric preheating, electric reheating - - 90 - 50/60 2000 III - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 75 - - 700 30 25 - 55 G4 G4 + F7 (Option: H13) - - 25 - - 650 7.2 - 30 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-200 ERV WiFi
Speed IV
230 - - polymer coated steel - electric preheating, electric reheating - - 120 - 50/60 2000 IV - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 68 - - 700 30 33 - 55 G4 G4 + F7 (Option: H13) - - 44 - - 650 7.2 - 36 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E2-200 ERV WiFi
Speed V
230 - - polymer coated steel - electric preheating, electric reheating - - 200 - 50/60 2000 V - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -15...+40 - - 66 - - 700 30 56 - 55 G4 G4 + F7 (Option: H13) - - 134 - - 650 7.2 - 45 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV WiFi Speed I 230 - - polymer coated steel - electric reheating - - 30 - 50/60 2200 I - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 96 - - 350 10 8 - 31 G4 G4 - - 20 0.4 1.94 - - - 13 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV WiFi Speed II 230 - - polymer coated steel - electric reheating - - 44 - 50/60 2200 II - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 94 - - 350 10 12 - 31 G4 G4 - - 23 0.4 1.94 - - - 20 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV WiFi Speed III 230 - - polymer coated steel - electric reheating - - 60 - 50/60 2200 III - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 92 - - 350 10 17 - 31 G4 G4 - - 29 0.4 1.94 - - - 27 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV WiFi Speed IV 230 - - polymer coated steel - electric reheating - - 75 - 50/60 2200 IV - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 89 - - 350 10 21 - 31 G4 G4 - - 37 0.4 1.94 - - - 33 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV WiFi Speed V 230 - - polymer coated steel - electric reheating - - 100 - 50/60 2200 V - - - - - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 87 - - 350 10 28 - 31 G4 G4 - - 53 0.4 1.94 - - - 39 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV black
Speed I
230 wall mounting - polymer coated steel yes electric reheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 96 - - 350 10 8 - - G4 G4 - - 12 0.4 1.94 - - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV black
Speed II
230 wall mounting - polymer coated steel yes electric reheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 89 - - 350 10 17 - - G4 G4 - - 21 0.4 1.94 - - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100 ERV black
Speed III
230 wall mounting - polymer coated steel yes electric reheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow enthalpic membrane - - - - 100 - - - -20...+40 - - 83 - - 350 10 28 - - G4 G4 - - 45 0.4 1.94 - - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100
Speed I
230 wall mounting - polymer coated steel yes electric reheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 98 - - 350 10 8 - - G4 G4 - - 12 0.4 1.94 - - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100
Speed II
230 wall mounting - polymer coated steel yes electric reheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 92 - - 350 10 17 - - G4 G4 - - 21 0.4 1.94 - - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Freshbox E1-100
Speed III
230 wall mounting - polymer coated steel yes electric reheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow polystyrene - - - - 100 - - - -20...+40 - - 89 - - 350 10 28 - - G4 G4 - - 45 0.4 1.94 - - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - -
Vento Expert A50-1 S Pro
(1 speed)
100-240 - 160 - yes - 0.025 - - - 50/60 800 - - - - - 3.61 - - IP24 - - - - - - - - - 15 8 G3 (F8 PM2.5 > 99 %) -20…+40 42 - - - - - - - 1.73 - - - 4 2 - - - - - 20 11 - up to 93 - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 S2 -
Vento Expert A50-1 S Pro
(2 speed)
100-240 - 160 - yes - 0.03 - - - 50/60 1300 - - - - - 4.15 - - IP24 - - - - - - - - - 30 15 G3 (F8 PM2.5 > 99 %) -20…+40 42 - - - - - - - 1.00 - - - 8 4 - - - - - 27 18 - up to 93 - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 S2 -
Vento Expert A50-1 S Pro
(3 speed)
100-240 - 160 - yes - 0.039 - - - 50/60 1900 - - - - - 5.20 - - IP24 - - - - - - - - - 50 25 G3 (F8 PM2.5 > 99 %) -20…+40 42 - - - - - - - 0.75 - - - 14 7 - - - - - 30 21 - up to 93 - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 S2 -
CIVIC EC LB 1200 S21 400 floor mounting - polymer coated steel yes - - - 1240 - 50/60 3630 - - - Supply and exhaust 394 - - A+ - 3 - counter-flow polystyrene - 34 24 -25...+40 400 - - - - - 40 mm mineral wool 84…96* - 350 - - 344 - - G4 G4 + (option: F7) - - - 2.1 2.1 - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8.
Vento Expert A50-1 S10 Pro
(1 speed)
100-240 - 160 - yes - 0.025 - - - 50/60 800 - - - - - 3.61 - - IP24 - - - - - - - -20…+40 - 15 8 - - 42 - - - - - - - 1.73 - - - 4 2 - - - - - 20 11 G3 (Option: F8 PM2,5 > 99 %*) up to 93 - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 S2 -
Vento Expert A50-1 S10 Pro
(2 speed)
100-240 - 160 - yes - 0.030 - - - 50/60 1300 - - - - - 4.15 - - IP24 - - - - - - - -20…+40 - 30 15 - - 42 - - - - - - - 1.00 - - - 8 4 - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 93 - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 S2 -
Vento Expert A50-1 S10 Pro
(3 speed)
100-240 - 160 - yes - 0.039 - - - 50/60 1900 - - - - - 5.20 - - IP24 - - - - - - - -20…+40 - 50 25 - - 42 - - - - - - - 0.75 - - - 14 7 - - - - - 30 21 G3 (Option: F8 PM2,5 > 99 %*) up to 93 - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 S2 -
CIVIC EC LB 300 S21 230 floor mounting - polymer coated steel yes without heating - - 320 - 50/60 2150 - - - Supply and exhaust 138±3% - - A - 1 21 counter-flow polystyrene - - - -25...+40 200 - - - - - 40 mm mineral wool 78...92* - 125 - - 89 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 0.9 0.9 - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8.