Blauberg KOMFORT Ultra EC L2 300

KOMFORT Ultra EC L2 300
KOMFORT Ultra EC L2 300
zoom

Compact heat recovery air handling units. Maximum air flow up to 300 m³/h.
Model features
  • Description
  • Modifications
  • Downloads
  • Designation key
  • BIM
  • Accessories
Description
Description
FEATURES

Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.The heat recovery technology is used to minimize ventilation heat losses.Control of air exchange for creating comfortable indoor microclimate.Compatible with round ∅ 125 mm air ducts.

DESIGN FANS

The casing of KOMFORT Ultra EC L2 300-E S14 white is made of double skinned white painted metal panels, internally filled with 20 mm mineral wool layer for heat- and sound insulation.The spigots are located at the sides of the unit and are equipped with rubber seals for airtight connection to the air ducts.The hinged panel of the casing ensures easy access to the unit internals for service works including cleaning, filter replacement, etc.

The unit is equipped with high efficient external rotor EC motors and centrifugal impellers with forward curved blades.EC motors have the best power consumption to air flow ratio and meet the latest demands concerning energy saving and high efficient ventilation.EC motors are featured with high performance, low noise level and totally controllable speed range.The impellers are dynamically balanced.

HEAT RECOVERY CONTROL AND AUTOMATION

The KOMFORT Ultra EC L2 300-E ... white unit is equipped with an enthalpy plate cross-flow heat exchanger for enegry (heat and humidity) recovery. Due to humidity recovery condensate is not generated in the enthalpy heat exchanger.The air flows are completely separated in the heat exchanger. Thus smells and contaminants are not transferred from the extract air to the supply air.Heat recovery is based on heat and/or humidity transfer through the heat exchanger plates. In the cold season supply air is heated in the heat exchanger by transferring the heat energy of warm and humid extract air to the cold fresh air. Heat recovery minimizes ventilation heat losses and heating costs respectively.In the warm season the heat exchanger performs reverse and intake air is cooled in the heat exchanger by the cool extract air. That reduces operation load on air conditioners and saves electricity.When the indoor and outdoor temperature difference is insignificant, heat recovery is not reasonable. In this case the heat exchanger can be temporary replaced with a summer block for the warm season (available as a specially ordered accessory).

The KOMFORT Ultra EC L2 300-E S14 white units have an integrated control system with a wall-mounted control panel S14 with a LED indication.

The S14 control panel functions:

  • Unit On/Off.
  • Speed selection: Low, Medium or High.
  • Activation of the summer ventilation mode: The supply fan stops and the extract fan continues its operation with no heat recovery.
  • Alarm indication.
  • Filter maintenance indication.

The KOMFORT Ultra EC L2 300-E S14 white unit is equipped with a USB connector (Type B) and can be connected to a PC for configuring the advanced settings in a special software:

  • Fan speed adjustment from 0 to 100 %. Each speed is individually adjusted for the supply and the extract fans.
  • Operation control on feedback from the FS2 duct humidity sensor (to be ordered separately).
  • Unit operation setting according to the external relay (to be ordered separately).
  • Temperature setting for freeze protection system activation.
  • Control and operation adjustment of the filter maintenance timer.
  • External control unit and humidity level control.
  • Software version upgrading.
FREEZE PROTECTION

The integrated automatic freeze protection is used to prevent freezing of the heat exchanger in the cold season. The supply fan turns off according to the temperature sensor to get the heat exchanger warmed up with extract air. After that the supply fan turns on and the unit continues to run in the standard mode.

AIR FILTRATION

Two built-in G4 and F8 filters provide efficient supply air filtration.The G4 filter is used for extract air filtration.

Modifications
Modification name
KOMFORT Ultra EC L2 300-E S14 white
+
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
KOMFORT Ultra EC L2 300 - data sheet (pdf 1.19Mb)
KOMFORT Ultra EC L2 300 - user's manual (pdf 12.37Mb)
KOMFORT Ultra EC L2 300 - image (png 385.2Kb)
S14 / S15 automation - software (zip 13.08Mb)
Designation key
Designation key
Series Unit type Motor type Spigot modification Insulation Rated air flow [m³/h]   Heat exchanger type Control Casing
KOMFORT Ultra: compact unit ЕС: electronically commutated motor L: horizontal spigot orientation 2: insulation 20 mm 300 Е: energy recovery S14: sensor control panel with LED indication white: painted steel
BIM
BIM

Accessories
Accessories
    KOMFORT Ultra EC L2 300-E S14 white
G4 panel filter FP 240x184x40 G4
F8 panel filter FP 240x184x40 F8
Internal humidity sensor FS2
CO2 sensor with indication CD-1
CO2 sensor CD-2
Humidity sensor HR-S
Silencer SD 125
Silencer SDF 125
Backdraft air damper VRV 125
Air damper VKA 125
Electric actuator LF230
Summer block SB C4 200/240